Data: 2009-07-22 17:45:59 | |
Autor: Grzegorz Szymczykiewicz | |
dysk twardy - Palimpsest Disk Utility 0.3 mĂłwi o b ĹÄdzie | |
Po zainstalowaniu nowej wersji fedory (11), za kaĹźdym razem po uruchomieniu systemu dostajÄ komunikat o bĹÄdzie dysku(z programu Palimpsest Disk Utility 0.3). w detalach przy jednym parametrze jest FAILING
1 Read Error Rate current: 200 worst: 1 threshold: 51 value: 0 status: FAILING type: pre-fail updates: online Reszta parametrĂłw jest ok. Co oznacza ten bĹÄ d? Czy powinienem siÄ martwiÄ i szykowaÄ kasÄ na nowy dysk? Czy to jeszcze nic strasznego? ZaĹÄ czam poniĹźej wynik programu smartctl -- all /dev/sdb. WyĹwietla on kilka informacji o bĹÄdach, czy dobrze rozumiem Ĺźe wystÄ piĹy one dawno temu (at disk power-on lifetime: 840 hours)? smartctl version 5.38 [i386-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Western Digital Caviar family Device Model: WDC WD800BB-00DKA0 Serial Number: WD-WCAHL4001472 Firmware Version: 77.07W77 User Capacity: 80,023,182,848 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Wed Jul 22 17:37:58 2009 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (2475) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 38) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 200 001 051 Pre-fail Always In_the_past 0 3 Spin_Up_Time 0x0007 099 089 021 Pre-fail Always - 1575 4 Start_Stop_Count 0x0032 092 092 040 Old_age Always - 8960 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 253 051 Pre-fail Always - 0 9 Power_On_Hours 0x0032 079 079 000 Old_age Always - 15335 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 092 092 000 Old_age Always - 8785 194 Temperature_Celsius 0x0022 103 253 000 Old_age Always - 40 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0012 200 200 000 Old_age Always - 0 199 UDMA_CRC_Error_Count 0x000a 200 253 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0009 200 085 051 Pre-fail Offline - 0 SMART Error Log Version: 1 ATA Error Count: 47457 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 47457 occurred at disk power-on lifetime: 840 hours (35 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 40 8a 96 81 e5 Error: Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 00 00 c8 00 00 40 00 00 00:13:57.100 NOP [Abort queued commands] 01 00 c6 00 00 16 bd 00 00:13:57.100 [RESERVED] 00 00 ca 00 00 08 00 00 00:13:57.100 NOP [Abort queued commands] 00 00 c8 00 00 08 00 00 00:13:57.100 NOP [Abort queued commands] 05 00 81 00 00 4f 96 00 00:13:57.100 [RESERVED] Error 47456 occurred at disk power-on lifetime: 840 hours (35 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 40 8a 96 81 e5 Error: Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 00 00 c8 00 00 40 00 00 00:13:55.100 NOP [Abort queued commands] 01 00 c6 00 00 d6 bf 00 00:13:55.100 [RESERVED] 00 00 ca 00 00 08 00 00 00:13:55.100 NOP [Abort queued commands] 00 00 00 00 00 00 00 00 00:13:55.100 NOP [Abort queued commands] 00 00 ca 00 00 08 00 00 00:13:55.100 NOP [Abort queued commands] Error 47455 occurred at disk power-on lifetime: 840 hours (35 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 40 8a 96 81 e5 Error: Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 00 00 c8 00 00 40 00 00 00:13:53.200 NOP [Abort queued commands] 00 00 c8 00 00 20 00 00 00:13:53.200 NOP [Abort queued commands] 00 00 60 00 00 8f 7b 00 00:13:53.200 NOP [Abort queued commands] 00 00 ca 00 00 08 00 00 00:13:53.200 NOP [Abort queued commands] 05 00 81 00 00 4f 96 00 00:13:53.200 [RESERVED] Error 47454 occurred at disk power-on lifetime: 840 hours (35 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 40 8a 96 81 e5 Error: Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 00 00 c8 00 00 40 00 00 00:13:51.150 NOP [Abort queued commands] 01 00 c6 00 00 f6 bc 00 00:13:51.150 [RESERVED] 00 00 ca 00 00 08 00 00 00:13:51.150 NOP [Abort queued commands] 00 00 c8 00 00 01 00 00 00:13:51.150 NOP [Abort queued commands] 07 00 94 00 00 bf 4b 00 00:13:51.150 [RESERVED] Error 47453 occurred at disk power-on lifetime: 840 hours (35 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 40 8a 96 81 e5 Error: Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 00 00 c8 00 00 40 00 00 00:13:49.200 NOP [Abort queued commands] 01 00 c6 00 00 46 bf 00 00:13:49.200 [RESERVED] 00 00 ca 00 00 10 00 00 00:13:49.200 NOP [Abort queued commands] 00 00 00 00 00 d7 4d 00 00:13:49.200 NOP [Abort queued commands] 00 00 c8 00 00 01 00 00 00:13:49.200 NOP [Abort queued commands] SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 41 - # 2 Short offline Completed without error 00% 41 - # 3 Conveyance offline Completed without error 00% 77 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. -- Pozdrawiam Grzegorz |
|
Data: 2009-07-26 14:05:34 | |
Autor: Radosław Sokół | |
dysk twardy - Palimpsest Disk U tility 0.3 mówi o błędzie | |
W dniu 22.07.2009 17:45, Grzegorz Szymczykiewicz pisze:
1 Read Error Rate current: 200 worst: 1 threshold: 51 value: 0 status: Oznacza, że w jakimś momencie pracy dysku wystąpiło sporo błędów odczytu. Trudno dociekać przyczyny, mogło to być na- trafienie przez dysk na uszkodzony obszar (wyłączony potem z użycia). Wskaźnik jednak wrócił do normalnej wartości, więc dysk nie jest "umierający". Warto na pewno poobserwo- wać, czy ta wartość znowu nie będzie spadać (im mniej, tym gorzej) i jak zwykle warto mieć kopię zapasową danych, ale nie ma raczej powodu do paniki. -- |""""""""""""""""""""""""""""""""""""""""""""""""""""""""""| | Radosław Sokół | http://www.grush.one.pl/ | | | Politechnika Śląska | \................... Microsoft MVP ......................../ |
|
Data: 2009-07-27 12:41:08 | |
Autor: Grzegorz Szymczykiewicz | |
dysk twardy - Palimpsest Disk U tility 0.3 mówi o błędzie | |
W dniu 26.07.2009 14:05, Radosław Sokół pisze:
Oznacza, że w jakimś momencie pracy dysku wystąpiło sporo Dzięki za pomoc:) czegoś takiego się spodziewałem, ale nie byłem pewien. -- Pozdrawiam Grzesiek |
|